| (Mini solar charge controllers) |
1. Overloading protection
2. Short circuit protection
3. Reverse current protection
4. Reverse polarity connection protection |
5. Thunder protection
6. Over discharge protection
7. Overcharge protection
8. The temperature compensation
|
TECHNICAL INDEX (DC 12V Power supply condition)
Model |
CMP12 5A
|
CMP12 6A
|
CMP12 8A
|
CMP12 10A
|
CMP12 12A
|
Rated Voltage |
12V¡¢24V¡¢Automatic distinguish voltage
|
12V¡¢24V¡¢Automatic distinguish voltage
|
12V¡¢24V¡¢Automatic distinguish voltage
|
12V¡¢24V¡¢Automatic distinguish voltage
|
12V¡¢24V¡¢Automatic distinguish voltage
|
Loading current Max |
¡Ü5A |
¡Ü6A |
¡Ü8A |
¡Ü10A |
¡Ü12A |
Full charge cut |
13.7V |
13.7V |
13.7V |
13.7V |
13.7V |
Low voltage cut |
10.5~11V |
10.5~11V |
10.5~11V |
10.5~11V |
10.5~11V |
Temperature compensation |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
No load loss |
¡Ü20mA |
¡Ü20mA |
¡Ü20mA |
¡Ü20mA |
¡Ü20mA |
Wire area Min |
2.5m©O |
2.5m©O |
2.5m©O |
2.5m©O |
2.5m©O |
Voltage drop |
<120mv |
<140mv |
<160mv |
<200mv |
<210mv |
|
| |
(Medium solar charge controllers) |
1.Overloading protection
2.Short circuit protection
3.Reverse current protection
4.Reverse polarity connection protection
5. Thunder protection |
6. Over discharge protection
7. Overcharge protection
8. The temperature compensation
9. The data alternant on LCD display
|
TECHNICAL INDEX (DC 12V Power supply condition)
Model |
CMP24 16A
|
CMP24 20A
|
CMP24 24A
|
Rated Voltage |
12V¡¢24V¡¢ Automatic distinguish voltage
|
12V¡¢24V¡¢ Automatic distinguish voltage
|
12V¡¢24V¡¢ Automatic distinguish voltage
|
Loading current Max |
¡Ü16A |
¡Ü20A |
¡Ü24A |
Full charge cut |
13.7V |
13.7V |
13.7V |
Low voltage cut |
10.5~11V |
10.5~11V |
10.5~11V |
Temperature compensation |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
No load loss |
¡Ü30mA |
¡Ü30mA |
¡Ü30mA |
Wire area Min |
4m©O |
4m©O |
4m©O |
Voltage drop |
<200mv |
<240mv |
<280mv |
|
| |
(Intelligent solar charge controllers) |
1.Overloading protection
2. Short circuit protection
3. Reverse current protection
4. Reverse polarity connecting protection
5. Thunder and lighting protection
6. Over discharge protection
7. Over charge protection
8. Battery stop being charged at the voltage level, HVD sets up
| 9. Battery turn off at the voltage level, LVD sets up
10. Display the capacity of the battery SOC
11. Load turns on work, setup reset
12. Intelligentized the temperature compensation
13. Memorize accumulated charging ampere hours on the LCD screen
14. Memorize accumulated loading ampere hours on the LCD screen
15. CPU control and LCD display
|
TECHNICAL INDEX (DC 12V Power supply condition)
Model |
CMP45 30A
|
CMP45 40A
|
CMP45 45A
|
Rated Voltage |
12V¡¢24V¡¢ Automatic distinguish voltage
|
12V¡¢24V¡¢ Automatic distinguish voltage
|
12V¡¢24V¡¢ Automatic distinguish voltage
|
Loading current Max |
¡Ü30A |
¡Ü40A |
¡Ü45A |
Full charge cut |
13.7V Default, can be reset
|
13.7V Default, can be reset
|
13.7V Default, can be reset
|
Low voltage cut |
10.5V Default, can be reset
|
10.5V Default, can be reset
|
10.5V Default, can be reset
|
Temperature compensation |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
-3mv/¡æ/cell |
No load loss |
¡Ü45mA |
¡Ü45mA |
¡Ü45mA |
Wire area Min |
6m©O |
6m©O |
6m©O |
Voltage drop |
<200mv |
<240mv |